Case Study

Robotic Test System

A client required a robotic actuator test system that incorporated a test set to test power management panels for the Boeing 777X programme. The panel had a large number of circuit breakers that were required to be operated during an acceptance test procedure.

The test set supplied AC and DC power as well as discrete and analogue signals, with communications via ARINC629.

The robotic actuator test system ensured the breakers were in the correct position and checked via a vision system whether the breaker ratings were correct. The robotic head was aligned using a vision system and specialised lighting to reflect the edge of the breaker to locate its exact position.

A laser distance measurement was required to locate the top of the head. This, combined with a load cell and a three-jaw gripper, allowed the breaker to be pushed in or pulled out without exerting excessive force.

The tests were executed by a S/W application (Test Manager) which executed on the test station PC. As well as communicating with the devices on the test station, communications with the actuator PLC were also executing in parallel.